The VFC2000-MT is a low-cost temperature monitoring system for vaccines, recording temperatures as low as -100 °C (-148 °F). Includes ISO17025 accredited calibration certificate
Key Features:
  • VFC & CDC Compliant
  • Audible & Visual Alarms
  • Temperature Check Reminder
  • Annual or Biennial Calibration Option
VFC2000-MT
The VFC2000-MT is a simple, low-cost temperature monitoring system for vaccines. The VFC2000-MT is designed to comply with all CDC and VFC requirements and provides precise, continuous temperature monitoring and validation for temperatures as low as -100 °C (-148 °F).

Featuring a convenient LCD screen, the VFC2000-MT displays current, minimum, and maximum readings as well as a battery level indicator. The VFC2000-MT is also equipped with an LED reminder to conduct the required 24-hour temperature check. If temperatures fluctuate out-of-range, the VFC2000-MT triggers an audio and visual alert.

The VFC2000-MT is compatible with the latest MadgeTech 4 Software making starting, stopping, and downloading simple and easy. Graphical and tabular data is provided for analysis and can be viewed using the software which supports customizable engineering units.
General
Temperature
Memory
16,128 readings (all channels enabled)
Reading Rate
1 reading every second up to 1 reading every 24 hours
Cold Junction Compensation
Automatic based on internal channel
Battery Life
3 years typical at 1 minute reading rate
Material
ABS plastic
Required Interface Package
USB to Mini USB Cable
Operating Environment
-20 °C to +60 °C (-4 °F to +140 °F), 0 %RH to 95 %RH non-condensing
Dimensions
3.0 in x 3.5 in x 0.95 in (76.2 mm x 88.9 mm x 24.1 mm) - Data logger only
Internal Channel Temperature Range
-20 °C to 60 °C (-4 °F to +140 °F)
Internal Channel Temperature Senso
Semiconductor
Internal Channel Temperature Calibrated Accuracy
±0.5 °C (0 °C to +50 °C)
Internal Channel Temperature Resolution
0.01 °C (0.18 °F)
Remote Channel (Glycol Bottle) Temperature Range
-50 °C to +80 °C (-58 °F to +176 °F)
Remote Channel Temperature Calibrated Accuracy
±0.5 °C
Remote Channel Temperature Resolution
0.1 °C (0.18 °F)
Remote Channel Temperature Sensor
Type K Thermocouple (Included)
Remote Channel (Thermocouple) Temperature Range
-100 °C to +80 °C (-148 °F to +176 °F)
Weight
1.1250 LBS
Baud Rate
250,000
ULT90 Product User Guide
VFC2000-MT (30ml) — 902238-00 VFC2000-MT (No Glycol Bottle) — 902311-00
Contact
LLC DATA LOGION

Office 53, 42 Pobedy Boulevard, Voronezh 394077, Russian Federation

+ 7 (951) 862-38-07
info@datalogion.ru
© 2025 LLC DATA LOGION
Office 53, 42 Pobedy Boulevard, Voronezh 394077, Russian Federation
ADRESS
Services
Software
INFO